Installing a new vanity, and like idiots, we forgot to account for a floating cabinet when plumbing hookups went in, so the drain outlets have about 3-4 inches clearance below, but there’s plenty of space otherwise. The plan is actually to try some waterless valve traps anyway, but if we don’t like them, or there’s some future inspection issue, can it simply be sloped up at a 1/4 -1/2 in grade? Maybe also with some bends to save space?
My plumber comes to install in a few days, and I’d like to know how much of an idiot he’ll call me
It sounds like you’re probably good.
The slope itself shouldn’t matter as long as the drain hole at the bottom of the sink is still higher than the drain hole in the wall. You can also angle the p-trap itself a little bit, but it still needs to be able to hold enough water in the bottom to block the pipe.
Oh I see. Yes, the sink is set about 20 inches above the wall hookup.